Fluoropolymer Tubing

Optinova can extrude a variety of fluoropolymers, including PTFE, FEP, PFA, ETFE, PVDF, MFA and PEEK. By combining unique material properties with advanced production processes, we offer customers high-quality, customizable tubing solutions.

Quality inspection is done at every stage of the extrusion process. Optinova tubing receives frequent testing for consistent tensile strength, elongation and bending ratio.

View certifications
Optinova_Group_Fluoropolymer_Tubing_PTFE

Quality inspection is done at every stage of the extrusion process. Optinova tubing receives frequent testing for consistent tensile strength, elongation and bending ratio.

View certifications
Min/Max Service temp.
Units
°C
PTFE
-240/260
FEP
-200/200
PFA
-200/260
PVDF
-60/150
ETFE
-190/150
Melting point
Units
°C
PTFE
330
FEP
257-275
PFA
300-310
PVDF
175
ETFE
270
Tensile strength
Units
MPa
PTFE
20-34
FEP
20-28
PFA
25-30
PVDF
35-50
ETFE
40-47
Elongation
Units
%
PTFE
200-400
FEP
300-325
PFA
300
PVDF
15-50
ETFE
230
Hardness
Units
Shore D
PTFE
55-65
FEP
55-60
PFA
55-64
PVDF
75-78
ETFE
63-75
Density
Units
g/cm3
PTFE
2,17
FEP
2,15
PFA
2,15
PVDF
1,8
ETFE
1,7
Water absorption
Units
%
PTFE
<0,01
FEP
<0,01
PFA
<0,03
PVDF
0,04
ETFE
0,02
Chemical resistance
Units
N/A
PTFE
Excellent
FEP
Very good
PFA
Excellent
PVDF
Very good
ETFE
Very good
Units PTFE FEP PFA PVDF ETFE
Min/Max Service temp. °C -240/260 -200/200 -200/260 -60/150 -190/150
Melting point °C 330 257-275 300-310 175 270
Tensile strength MPa 20-34 20-28 25-30 35-50 40-47
Elongation % 200-400 300-325 300 15-50 230
Hardness Shore D 55-65 55-60 55-64 75-78 63-75
Density g/cm3 2,17 2,15 2,15 1,8 1,7
Water absorption % <0,01 <0,01 <0,03 0,04 0,02
Chemical resistance N/A Excellent Very good Excellent Very good Very good

Contacts